[pdf]
1 AWG 1C Stranded Bare Copper Tape Shielded Red PVC RG7H1R 6/10KV Medium Voltage CableAllowable Ampacity for 1 AWG 1C Stranded Bare Copper Tape Shielded Red PVC RG7H1R 6/10KV Medium Voltage Cable: 100 Amps
This cable is designed for power distribution in medium voltage applications. It has a conductor size of 1 AWG, made from stranded bare copper, which provides flexibility and good conductivity. The cable is shielded with a tape shield to protect against electromagnetic interference (EMI), ensuring that the power quality is maintained. It's rated for voltages up to 6/10KV, making it suitable for use in industrial, commercial, and utility applications where medium voltage power is required. The red PVC (Polyvinyl Chloride) jacket not only provides mechanical protection but also helps in identifying the cable in installations.
• MV-105 Cable
• 1 AWG Medium Voltage Power Cable
• Red Jacketed Medium Voltage Cable
• Power distribution in medium voltage networks
• Industrial plants and factories for connecting power to machines and equipment
• Commercial buildings for main power supply
• Utility substations as part of the distribution network
• Renewable energy installations such as wind farms and solar panels for connecting to the grid
• IEEE 1202 (for flame testing)
• UL 1072 (for medium voltage power cables)
• ICEA S-93-639/NEMA WC 74 (for 5-46KV shielded power cables)
• ASTM B3 and B8 (for conductors)
• Conductor: Stranded red copper conductor Cl.2, acc.to IEC 60228
• Inner Semi-Conductive Layer: Extruded elastomeric compound
• Insulation: Rubber type G7
• Outer Semi-Conductive Layer: : Extruded elastomeric compound
• Screen: Red copper wires and one or two copper tape(s) applied helically, if necessary
• Outer Sheath: Red (RAL 3000), PVC type RZ
• According to IEC CEI 20-13
• According to IEC 60502-2 (as far as applicable)
• According to IEC 60840 (26/45 kV)
• No. of cores x cross section n x mm²: 1x50
• AWG no.: 1
• Outer-Ø ca.mm ± 10%: 24,8
• Nominal Voltage: Uo/U 1,8/3 kV, Uo/U 3,6/6 kV, Uo/U 6/10 kV, Uo/U 8,7/15 kV, Uo/U 12/20 kV, Uo/U 18/30 kV Uo/U 26/45 kV
• Test voltage: Uo/U 1,8/3 kV = 6 kV, Uo/U 3,6/6 kV = 11 kV, Uo/U 6/10 kV = 17 kV, Uo/U 8,7/15 kV = 24 kV, Uo/U 12/20 kV = 29 kV, Uo/U 18/30 kV = 45 kV
• Temperature range: - 15° C up to + 90° C
• Max short circuit temperature: + 250° C
• Min installation temperature: 0° C
• Min. bending radius: 12 x d
• Max. tensile stress: 60 N/mm²
• Cable Weight approx. kg/km: 880
• Part Number: 48010QRL010M65
For all orders exceeding a value of 100USD shipping is offered for free.
Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.
Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.