[pdf]
1 AWG 3C Stranded Aluminium Shield Overall BC Tape Red PE ARG7H1EX 18/30KV Medium Voltage CableAllowable Ampacity for 1 AWG 3C Stranded Aluminium Shield Overall BC Tape Red PE ARG7H1EX 18/30KV Medium Voltage Cable: 100 Amps
This description pertains to a medium voltage cable that is rated for 18/30 kV (kilovolts) applications, indicating its suitability for higher voltage requirements compared to standard commercial or residential cables. The "1 AWG 3C" refers to a three-conductor cable where each conductor is 1 American Wire Gauge (AWG) in size, denoting thick conductors that can handle larger current loads.
Such a cable may be known by different names, reflecting its construction and application, such as "18/30 kV aluminum stranded medium voltage cable," "1 AWG triple-core aluminum shielded cable," or "medium voltage power cable with red PE insulation." These alternate names can vary but generally convey the cable's primary characteristics and applications.
It is designed for significant electrical installations where medium to high voltage power transmission is required. Typical applications include power distribution networks, connecting substations to industrial, commercial, or residential complexes, and providing power in environments where durability and reliability are critical, such as underground, outdoor, or industrial settings.
The cable should comply with international and national standards applicable to medium voltage power cables, ensuring its reliability, safety, and performance. This might include compliance with IEC 60502-2 for medium voltage cables or similar standards, dictating requirements for construction, performance, and testing.
• Conductor: Stranded plain aluminium conductor Cl.2, acc. to IEC 60228
• Inner Semi-Conductive Layer: Extruded Elastomeric Compound
• Insulation: Special EPR type DIH2
• Outer Semi-Conductive Layer: : Extruded Elastomeric Compound
• Screen: Red copper wires and one or two copper tape(s) applied helically.
• Outer Sheath: Red(RAL 3000), PE type DMZ1
• According to IEC 60502-2
• No. of cores x cross section n x mm²: 3 x 1 x 50
• AWG no.: 1
• Outer-Ø ca.mm ± 10%: 69
• Nominal Voltage: Uo/U 12/20 kV, Uo/U 18/30 kV
• Test Voltage: Uo/U 12/20 kV = 29 kV, Uo/U 18/30 kV = 45 kV
• Max. Operating Voltage: Uo/U 12/20 kV = Um 24 kV, Uo/U 18/30 kV = Um 36 kV
• Temperature range: - 25° C up to + 105° C
• Max short circuit temperature: + 300° C
• Min. bending radius: 13 x d
• Max. tensile stress: 60 N/mm²
• Cable Weight approx. kg/km: 3000
• Part Number: 48050XRL030M64
For all orders exceeding a value of 100USD shipping is offered for free.
Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.
Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.