• Underground primary residential and commercial distribution circuits.
• May be used in wet or dry locations, installed in underground ducts or direct burial.
1 AWG Copper TR-XLPE MV-90 cable, PVC concentric neutral cable 5kV-46kV, 1 AWG Medium voltage primary UD cable, 5 kV 46 kV MV-90 copper cable, 1 AWG TR-XLPE insulated underground cable.
• ICEA S-94-649: Standard for Concentric Neutral Rated Cables 5 – 46 kV.
• AEIC CS8: Specifications for Extruded Dielectric, Shielded Power Cable, Rated 5 – 46 kV.
Maximum operating voltage:
• 5 kV – 46 kV, 100 and 133% IL
Maximum conductor operation temperatures:
Wet and dry locations
For TR-XLPE
• Normal: 105 °C
• Emergency: 140 °C
• Short Circuit: 250 °C
For XLPE
• Normal: 90 °C
• Emergency: 130 °C
• Short Circuit: 250 °C
• Conductor: Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request: larger sizes
• Conductor Shield: Semi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.
• Insulation: Thermoset tree-retardant cross-linked polyethylene (TR-XLPE). On request: cross-linked polyethylene (XLPE).
• Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
• Concentric Neutral: Soft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.
• Binder Tape: A suitable polyester tape, as required.
• Jacket: Overlying (sleeve) black polyvinyl chloride (PVC)
• Low tension stripping compounds.
• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.
• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.
• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.
• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.
• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.
• Size: 1 AWG
• Number of Strands: 19
• Nominal OD Over Insulation (In): 0.54
• Number of Wires: 13
• Full Neutral Size: 12 AWG
• Jacket Thickness (mil): 80
• Approximate Outside Diameter (In): 0.95
• Approximate Net Weight lb/kft: 775